Ford FCSD TECHNICAL TRAINING FCS-14000-DL Manual do Utilizador Página 97

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 116
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 96
LESSON 3: POWERTRAIN
Monitoring The Substrate Temperature Sensor
Substrate Temperature Sensor
The TCM controls a number of high power solenoids and is surrounded by automatic transmission fluid. As a
result, the TCM can get very hot. If the temperature of the hardware rises above a predetermined temperature, the
TCM shuts down. Prior to shutting down, the TCM logs a fault code and illuminates the MIL. Following the shut
down, the transmission enters a mechanical limp-home mode. Monitoring of the substrate temperature is carried
out by a temperature-dependent resistor mounted in the processor.
2005 Expedition/Navigator New Model Technician Training 02-SEP-04 3-61
Vista de página 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 115 116

Comentários a estes Manuais

Sem comentários